Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Increase of the concentration of dissolved copper in drinking water systems due to flow-induced nanoparticle release from surface corrosion by-products

  • Ignacio T. Vargas
  • , Juan P. Pavissich
  • , Tomás E. Olivares
  • , Gustavo A. Jeria
  • , Rodrigo A. Cienfuegos
  • , Pablo A. Pastén
  • , Gonzalo E. Pizarro

Producción científica: Contribución a una revista › Artículo › revisión exhaustiva

22 Citas (Scopus)

Resumen

Standard measurements of dissolved copper are made by filtering water samples through 0.45. μm pore-size membranes. However, the surface of corroding metallic surfaces may be covered by topographic features. <. 0.2. μm and structures that can be detached into the bulk water as nano-sized particles. A SEM, EDX, and AFM characterization of a corroding pipe after flow events revealed surface cavities, detached particles and attached particles with sizes between 0.05 and 0.2. μm. Our findings show that the release of colloidal and nanoparticles of corrosion by-products into the water can result in an increase of the dissolved copper measurements.

Idioma originalInglés
Páginas (desde-hasta)3492-3503
Número de páginas12
PublicaciónCorrosion Science
Volumen52
N.º10
DOI
EstadoPublicada - oct 2010
Publicado de forma externaSí

Huella

Profundice en los temas de investigación de 'Increase of the concentration of dissolved copper in drinking water systems due to flow-induced nanoparticle release from surface corrosion by-products'. En conjunto forman una huella única.

Citar esto