TY - JOUR
T1 - Ensuring Distribution Network Integrity Using Dynamic Operating Limits for Prosumers
AU - Petrou, Kyriacos
AU - Procopiou, Andreas T.
AU - Gutierrez-Lagos, Luis
AU - Liu, Michael Z.
AU - Ochoa, Luis F.
AU - Langstaff, Tom
AU - Theunissen, John M.
N1 - Publisher Copyright:
© 2010-2012 IEEE.
PY - 2021/9
Y1 - 2021/9
N2 - The number of residential consumers with solar PV and batteries, aka prosumers, has been increasing in recent years. Incentives now exist for prosumers to operate their batteries in more profitable ways than self-consumption mode. However, this can increase prosumer exports or imports, resulting in power flows that can lead to voltage and thermal limit violations in distribution networks. This work proposes a framework for Distribution Network Operators (DNOs) to ensure the integrity of MV-LV networks by using dynamic operating limits for prosumers. Periodically, individual prosumers send their intended operation (net exports/imports) as determined by their local control to the DNO who then assesses network integrity using smart meter data and a power flow engine. If a potential violation is detected, their maximum operating limits are determined based on a three-phase optimal power flow that incorporates network constraints and fairness aspects. A real Australian MV feeder with realistically modelled LV networks and 4,500+ households is studied, where prosumers' local controls operate based on energy prices. Time-series results demonstrate that the proposed framework can help DNOs ensure network integrity and fairness across prosumers. Furthermore, it unlocks larger profitability for prosumers compared with the use the 5kW fixed export limit adopted in Australia.
AB - The number of residential consumers with solar PV and batteries, aka prosumers, has been increasing in recent years. Incentives now exist for prosumers to operate their batteries in more profitable ways than self-consumption mode. However, this can increase prosumer exports or imports, resulting in power flows that can lead to voltage and thermal limit violations in distribution networks. This work proposes a framework for Distribution Network Operators (DNOs) to ensure the integrity of MV-LV networks by using dynamic operating limits for prosumers. Periodically, individual prosumers send their intended operation (net exports/imports) as determined by their local control to the DNO who then assesses network integrity using smart meter data and a power flow engine. If a potential violation is detected, their maximum operating limits are determined based on a three-phase optimal power flow that incorporates network constraints and fairness aspects. A real Australian MV feeder with realistically modelled LV networks and 4,500+ households is studied, where prosumers' local controls operate based on energy prices. Time-series results demonstrate that the proposed framework can help DNOs ensure network integrity and fairness across prosumers. Furthermore, it unlocks larger profitability for prosumers compared with the use the 5kW fixed export limit adopted in Australia.
KW - Battery energy storage systems
KW - PV systems
KW - distribution networks
KW - optimal power flow
UR - http://www.scopus.com/inward/record.url?scp=85107192754&partnerID=8YFLogxK
U2 - 10.1109/TSG.2021.3081371
DO - 10.1109/TSG.2021.3081371
M3 - Article
AN - SCOPUS:85107192754
SN - 1949-3053
VL - 12
SP - 3877
EP - 3888
JO - IEEE Transactions on Smart Grid
JF - IEEE Transactions on Smart Grid
IS - 5
M1 - 9432974
ER -