N2 - Several code-conforming reinforced concrete buildings were severely damaged during the 2010 moment magnitude (M w ) 8.8 Chile earthquake, raising concerns about their real collapse margin. Although critical updates were introduced into the Chilean design codes after 2010, guidelines for collapse risk assessment of Chilean buildings remain insufficient. This study evaluates the collapse potential of a typical dual system (shear walls and moment frames) office building in Santiago. Collapse fragility functions were obtained through incremental dynamic analyses using a state-of-the-art finite element model of the building. Site-specific seismic hazard curves were developed, which explicitly incorporated epistemic uncertainty, and combined with the collapse fragility functions to estimate the mean annual frequency of collapse (λ c ) values and probabilities of collapse in 50-years (P c (50)). Computed values of λ c and P c (50) were on the order of 10 −5 –10 −4 , and 0.1–0.7%, respectively, consistent with similar studies developed for buildings in the US. The results also showed that the deaggregation of λ c was controlled by small to medium earthquake intensities and that different models of the collapse fragility functions and hazard curves had a non-negligible effect on λ c and P c (50), and thus, propagation of uncertainty in risk assessment problems must be adequately taken into account.
AB - Several code-conforming reinforced concrete buildings were severely damaged during the 2010 moment magnitude (M w ) 8.8 Chile earthquake, raising concerns about their real collapse margin. Although critical updates were introduced into the Chilean design codes after 2010, guidelines for collapse risk assessment of Chilean buildings remain insufficient. This study evaluates the collapse potential of a typical dual system (shear walls and moment frames) office building in Santiago. Collapse fragility functions were obtained through incremental dynamic analyses using a state-of-the-art finite element model of the building. Site-specific seismic hazard curves were developed, which explicitly incorporated epistemic uncertainty, and combined with the collapse fragility functions to estimate the mean annual frequency of collapse (λ c ) values and probabilities of collapse in 50-years (P c (50)). Computed values of λ c and P c (50) were on the order of 10 −5 –10 −4 , and 0.1–0.7%, respectively, consistent with similar studies developed for buildings in the US. The results also showed that the deaggregation of λ c was controlled by small to medium earthquake intensities and that different models of the collapse fragility functions and hazard curves had a non-negligible effect on λ c and P c (50), and thus, propagation of uncertainty in risk assessment problems must be adequately taken into account.
KW - Chilean code-conforming building
KW - Collapse assessment
KW - Incremental dynamic analyses
KW - Seismic hazard models
UR - http://www.scopus.com/inward/record.url?scp=85060162644&partnerID=8YFLogxK
U2 - 10.1016/j.engstruct.2019.01.006
DO - 10.1016/j.engstruct.2019.01.006
M3 - Article
AN - SCOPUS:85060162644
SN - 0141-0296
VL - 183
SP - 770
EP - 779
JO - Engineering Structures
JF - Engineering Structures
ER -